Liquid Natural Gas tanks |
|
Mugardos, La Coruña, España |
|
|
|
|
Typologie |
Hydraulic Structures |
Date |
Décembre, 2007 |
Maîtrise d'ouvrage |
Reganosa |
Constructeur |
Acciona |
|
|
Storage tanks are a significant part of any LNG project cost. There are several basic designs including single containment (with an inner container made of 9% Ni steel able to withstand cryogenic temperatures), double containment (in which an outer container made of concrete provides a second barrier to contain the leaks), and full containment tanks (in which an outer layer made of pre-stressed concrete completely encases the tank to provide a second containment system.)
FHECOR Ingenerios Consultores designed two double containment tanks with a capacity of 150.000 m3 according to API620 standard, for a LNG storage installation in Mugardos (La Coruña, Spain). In addition, all the foundations and structures related to the process plant were also designed by FHECOR.