Owner Reganosa
Construction Acciona
Storage tanks are a significant part of any LNG project cost. There are several basic designs including single containment (with an inner container made of 9% Ni steel able to withstand cryogenic temperatures), double containment (in which an outer container made of concrete provides a second barrier to contain the leaks), and full containment tanks (in which an outer layer made of pre-stressed concrete completely encases the tank to provide a second containment system.)

FHECOR Ingenerios Consultores designed two double containment tanks with a capacity of 150.000 m3 according to API620 standard, for a LNG storage installation in Mugardos (La Coruña, Spain). In addition, all the foundations and structures related to the process plant were also designed by FHECOR.
Pro
Storage tanks are a significant part of any LNG project cost. There are several basic designs including single containment (with an inner container made of 9% Ni steel able to withstand cryogenic temperatures), double containment (in which an outer container made of concrete provides a second barrier to contain the leaks), and full containment tanks (in which an outer layer made of pre-stressed concrete completely encases the tank to provide a second containment system.)
FHECOR Ingenerios Consultores designed two double containment tanks with a capacity of 150.000 m3 according to API620 standard, for a LNG storage installation in Mugardos (La Coruña, Spain). In addition, all the foundations and structures related to the process plant were also designed by FHECOR.
Liquid Natural Gas tanks
Mugardos, La Coruña, España
Structural typology Hydraulic Structures
Date December, 2007
Owner Reganosa
Construction Acciona
Scope Detailed design
Storage tanks are a significant part of any LNG project cost. There are several basic designs including single containment (with an inner container made of 9% Ni steel able to withstand cryogenic temperatures), double containment (in which an outer container made of concrete provides a second barrier to contain the leaks), and full containment tanks (in which an outer layer made of pre-stressed concrete completely encases the tank to provide a second containment system.)

FHECOR Ingenerios Consultores designed two double containment tanks with a capacity of 150.000 m3 according to API620 standard, for a LNG storage installation in Mugardos (La Coruña, Spain). In addition, all the foundations and structures related to the process plant were also designed by FHECOR.